Basic Info.
Function
Hot Water Boiler
Water Circulation
Forced Circulation
Drum Placement
Horizontal Boiler
Rated Thermal Load(Kw)
24
Rated Output Power(Kw)
20.7
Efficiency at Rated Thermal Load(%)
>107%
Boiler Size(mm)
760*400*310
Packing Size(mm)
856*480*411
One 40hq Container Load Quantities(PCS)
350
One 20FT Container Load Quantities(PCS)
150
Delivery Time
with in Two Weeks After Get Customer Payment
Production Ability(PCS)
20000/Month
Product Description
Technique details:
Type | LL1PBD18/20-H | LL1PBD24-H |
| Unit | LPG(Y) | NG(T) | LPG(Y) | NG(T) |
Gas pressure | Pa | 2800 | 2000 | 2800 | 2000 |
Rated input power(Heating load) | KW | 18/24 | 24 |
Rated output power | KW | 17.6/19.6 | 23.5 |
Minimum heating input power | KW | 5.4/6 | 7.2 |
Minimum heating output power | KW | 5.1/5.7 | 6.8 |
Minimum hot water input power | KW | 5.4/6 | 7.2 |
Minimum hot water output power | KW | 4.9/5.4 | 6.5 |
Nominal heating capacity | KW | 7.5/8.2 | 10 |
Efficiency (%) |
In condensing mode full power at 30/50ºC | % | 103.7% |
In normal mode at 60/8ºC | % | 97.1% |
Medium mode at 40/60ºC | % | 93.8% |
At minimum power at 40/60ºC | % | 91.16% |
At 30% of medium power at 30/50ºC | % | 99.07% |
Hot water pressure | Mpa | 0.03~0.8 |
Power supply | / | 220V-50HZ |
Rated power | W | 110 |
Protection degree | IP | X4D |
Heating area for reference | Sq.m | 100/120 | 140 |
Temperature Settings range of heating water | ºC | 30-80(floor heating: 30~60) |
Temperature Settings range of hot water | ºC | 30~60 |
Expansion tank capacity | L | 6 |
Expansion tank initial pressure | bar | 1 |
Heating pipes safety valve start-up pressure | Mpa | 0.3 |
Hot water pipes safety valve start-up pressure | Mpa | 0.8 |
Pump lift | m | 5 |
Dimension of the smoke exhaust pipe | mm | Coaxial double flue Φ60- Φ90 | Coaxial double flue Φ60- Φ100 |
Reference maximum consumption quantity-NG | (m³/h) | 0.54-1.8/0.6-2.0 | 0.72-2.40 |
Reference maximum consumption quantity-LPG | (m³/h) | 0.2-0.4/0.22-0.72 | 0.26-0.86 |
Flue length | m | 1 |
Connector size | inch | heating/ gas:3/4" hot water 1/2" |
Net weight | kg | 41 | 42 |
Normal working noise | dB | |
CE wall hung gas boiler!
Safety features:
-Triple overheat protection.
-Flameout protection.
-Reignition function.
-Defer ignition function.
-Anti-freezing function.
-Anti-lock function for pump.
-Overload protection for pump.
-Lightning strike protection.
-Overload protection for control system.
-Safety release function.
-Automatic circulation function of pump.
-Self-diagnostic function.
-Safety lock function.
-Automatic by-pass valve
Product characteristic:
-European Technology
-Provide both heating and shower water
-High efficiency and gas-saving
-Quietly working
-Intelligent and economical control system
-Easy operation with digital LCD screen
-Four section timer
-Remote controller optional
-Fashional appearance design
-High quality components with CE certificates
My direct contact information as below:
Ms grace lee
mobile:+86 18566290413
website:szhaydn.en.made-in-china.com